AD4170 no-OS driver

See drivers/adc/ad4170 (doxygen) for the Doxygen documentation.

Supported Devices

Overview

The AD4170-4 is a low noise, completely integrated analog front end built around a 24-bit sigma-delta ADC. A crosspoint multiplexer presents four differential or eight single-ended/pseudo-differential analog inputs to an ultra-low noise PGA with gains of 0.5 to 128, so low amplitude transducers can be wired directly to the device. Output data rates range from 7.6 SPS to 500 kSPS. Integrated blocks include a band gap reference with 5 ppm/degC typical drift brought out on REFOUT at 2.5 V, an internal oscillator, a temperature sensor, four matched programmable excitation current sources (10 uA to 1.5 mA), low-side power switches, a VBIAS generator, a 12-bit DAC, four GPIOs, and AC excitation support.

A 16 entry sequencer converts each enabled channel in a predetermined order. Every sequencer channel picks its analog input pair from the crosspoint mux and one of eight user-defined setups; a setup carries the PGA gain, reference selection and buffering, bipolar/unipolar span, filter type, filter word, chopping options, burnout current, and the offset and gain calibration registers. That lets transducer readings, system checks, and diagnostic measurements be interleaved without reprogramming the device between conversions.

The driver covers the following family members:

  • AD4170-4 - 4 differential/8 pseudo-differential inputs, 7.6 SPS to 500 kSPS, sinc5+avg, sinc5, sinc3, post filters and a user programmable FIR filter, 12-bit DAC, AC excitation. 32-lead 4 mm x 6 mm LFCSP.

  • AD4171-8 - 8 differential/16 pseudo-differential inputs, 7.6 SPS to 500 kSPS, sinc5+avg, sinc5, sinc3 and post filters only, 12-bit DAC, AC excitation. 40-lead 6 mm x 6 mm LFCSP.

  • AD4190-4 and AD4195-4 - 4 differential/8 pseudo-differential inputs, 3.8 SPS to 62.5 kSPS, sinc5+avg, sinc5, sinc3 and post filters only, no DAC and no AC excitation. The two parts differ in accuracy grade only. 32-lead 4 mm x 6 mm LFCSP.

All of them share the same register map and are driven through a common set of APIs; the active part is selected with the id field of struct ad4170_init_param.

Applications

  • Industrial process control: PLC/DCS modules

  • Temperature and pressure measurement

  • Medical and scientific instrumentation

  • Chromatography

  • Electrical test and measurement

  • Instrumentation

  • Weigh scale

AD4170 Device Configuration

Driver Initialization

The device is controlled over a 3- or 4-wire SPI interface, so a no_os_spi_init_param has to be provided. Up to three optional GPIOs may be described as well: gpio_sync_inb for the SYNC_IN pin, gpio_dig_aux1 for DIG_AUX1 and gpio_dig_aux2 for DIG_AUX2. DIG_AUX1 is normally wired as the data ready output, while DIG_AUX2 is driven by the host when it is configured as the LDAC or START input.

ad4170_init is the first API to be called. It resets the device, applies the requested SPI settings, verifies the product ID against the selected id, checks that the power-on reset flag is set, runs a scratchpad read/write test, and then writes the whole struct ad4170_config out: pin muxing, clock control, standby and power-down switch control, error enables, ADC control, all eight setups, the channels listed in channel_en together with the channel enable mask itself, reference control, VBIAS, pull-up currents, the four excitation current sources, the FIR control block and the DAC configuration. Make sure it returns 0.

ad4170_remove frees the descriptor and the GPIOs taken during init.

ad4170_config_reset is exported as the configuration the device holds after a hardware or software reset, and is a convenient starting point for an application configuration.

Because ad4170_init programs all AD4170_NUM_SETUPS setup banks, every setup has to be initialized, even the unused ones. A zeroed setup would be written out with an invalid filter word of 0.

SPI Interface Configuration

struct ad4170_spi_settings selects the flavour of the serial interface:

  • short_instruction - use the 7-bit addressing instruction instead of the default 15-bit one.

  • crc_enabled - enable CRC generation and checking on the communication.

  • sync_loss_detect - enable sync pattern loss detection and recovery.

ad4170_reset_spi_interface puts the serial interface back in a known state, and ad4170_reset performs a full software reset of the device.

Register Access

ad4170_spi_reg_read, ad4170_spi_reg_write and ad4170_spi_reg_write_mask give raw access to the register map. Register addresses are the AD4170_REG_* macros, which encode the transfer length in their upper bits, so the same API handles the 1 to 4 byte wide registers. ad4170_regmap dumps the register map to the console for debugging.

Channel and Setup Configuration

The sequencer holds AD4170_NUM_CHANNELS (16) channels and AD4170_NUM_SETUPS (8) setups.

  • ad4170_set_channel_map selects the positive and negative multiplexer inputs of a sequencer channel. Beside AIN0 to AIN16 and AINCOM, the mux also reaches the internal temperature sensor, the supply monitors, the DAC output, the LDO outputs, AVSS, DGND and the reference pins.

  • ad4170_set_channel_setup assigns one of the eight setups to a channel, plus the number of times the channel is repeated and the settling delay added after the channel switch.

  • ad4170_set_setup writes a full setup: the misc register (excitation current chopping, ADC/mux chopping, burnout current), the AFE register (reference buffers, reference selection, bipolar/unipolar span, PGA gain), the filter register (filter type and post filter), the filter word, and the offset and gain calibration values.

  • ad4170_set_channel_en enables the channels the sequencer converts.

Reference selection is per setup and picks REFIN1, REFIN2, the 2.5 V REFOUT or AVDD/AVSS. When REFOUT is used, the internal reference has to be turned on separately with ad4170_set_ref_control.

ADC Operating Mode

ad4170_set_adc_ctrl selects the operating mode along with parallel filter operation, the single versus per-channel data register selection, and the status byte appended in continuous read/transmit. The available modes are continuous conversion, continuous conversion with the FIR or the IIR filter, single conversion, standby, power-down, idle, and the four calibration modes (self and system, offset and gain).

The AD4171-8 has no FIR or IIR filter. ad4170_set_adc_ctrl returns -ENOTSUP when AD4170_MODE_CONT_FIR or AD4170_MODE_CONT_IIR is requested on it, and so does ad4170_set_fir_control. ad4170_init tolerates the latter, so an unused fir_control in the configuration does not make initialization fail on that part.

Reading Conversions

Conversion results can be fetched at several widths, with or without the status byte: ad4170_get_data16, ad4170_get_data16s, ad4170_get_data24, ad4170_get_data24s and ad4170_get_data32. When multi_data_reg_sel is set, ad4170_get_ch_data reads the per-channel data register of a given sequencer channel instead of the shared one.

The ad4170_read16, ad4170_read16s, ad4170_read24, ad4170_read24s and ad4170_read32 variants read a burst of samples in one go. ad4170_continuous_read streams samples in continuous read mode, and ad4170_continuous_read_exit leaves that mode. Continuous transmit over the TDM interface is left with ad4170_continuous_transmit_exit.

ad4170_get_status returns the data status register, whose RDY bit tells whether a new conversion is available. rdy_conv_timeout in the init parameters bounds how long the driver polls for end of conversion.

Clock Configuration

ad4170_set_clocksel picks the clock source: the internal oscillator, the internal oscillator with the clock output on XTAL2/CLKIO, an external clock on XTAL2/CLKIO, or an external crystal across XTAL1 and XTAL2/CLKIO. ad4170_set_mclk_div divides the master clock by 1, 2, 4 or 8, and ad4170_set_dclk_div divides the continuous transmit data clock.

Excitation, Bias and Power Switches

ad4170_set_current_source routes one of the four excitation current sources to an analog input, AINCOM or a GPIO, and sets its value to one of 0 uA, 10 uA, 50 uA, 100 uA, 250 uA, 500 uA, 1 mA or 1.5 mA. Currents can be summed by outputting more than one on the same pin.

ad4170_set_v_bias applies the VBIAS common-mode voltage to a mask of channels and ad4170_set_i_pullup enables the pull-up currents. ad4170_set_powerdown_sw drives the two low-side power switches, which are typically used to power down a bridge sensor between conversions, and ad4170_set_standby_ctrl selects which blocks stay alive in standby.

DAC

The AD4170-4 and the AD4171-8 embed a 12-bit DAC whose output spans 0 V to REFOUT or 0 V to 2 x REFOUT. ad4170_set_dac_config enables it and selects the span together with the hardware toggle and hardware LDAC modes. ad4170_set_dac_data writes the DAC register directly, while ad4170_set_dac_inputa and ad4170_set_dac_inputb load the two toggle registers. The output is then updated with ad4170_dac_sw_ldac, ad4170_dac_sw_toggle or ad4170_dac_hw_toggle, the last one driving the DIG_AUX2 pin.

FIR Filter

On the parts that have it, ad4170_set_fir_control selects the FIR mode - the default filter or a programmable one with odd/even symmetric, odd/even anti-symmetric or asymmetric coefficients - the coefficient set, and the number of coefficients, up to AD4170_FIR_COEFF_MAX_LENGTH (72). When a programmable mode is selected, the coefficients pointed to by fir_coefficients are written to the coefficient memory.

Diagnostics

ad4170_set_error_en selects which diagnostics raise an error: the ALDO and DLDO power supply monitors, the excitation current compliance checks, the reference and analog input overvoltage/undervoltage checks, the conversion error, and the memory map and ROM CRC checks. ad4170_get_error reads the error register and ad4170_set_error clears its sticky bits.

Pin Muxing

ad4170_set_pin_muxing configures DIG_AUX1 (disabled, data ready, SYNC_OUT or modulator data output), DIG_AUX2 (disabled, DAC LDAC, START input or modulator data output), the SYNC_IN pin, whether the active channel number is output on the GPIO pins, the digital output drive strength, and whether the interface resets on the last SCLK or on the CS edge.

AD4170 Driver Initialization Example

#define AD4170_SETUP_DEFAULT {                                  \
        .afe = {                                                \
                .ref_select = AD4170_REFIN_REFOUT,              \
                .bipolar = true,                                \
                .pga_gain = AD4170_PGA_GAIN_1,                  \
        },                                                      \
        .filter = {                                             \
                .filter_type = AD4170_FILT_SINC5_AVG,           \
                .post_filter_sel = AD4170_POST_FILTER_NONE,     \
        },                                                      \
        .filter_fs = 4,                                         \
        .gain = 0x555555,                                       \
}

struct ad4170_dev *ad4170_desc;
struct ad4170_init_param ad4170_ip = {
        .id = ID_AD4170,
        .spi_init = {
                .device_id = SPI_DEVICE_ID,
                .max_speed_hz = 10000000,
                .chip_select = GPIO_CS_PIN,
                .mode = NO_OS_SPI_MODE_3,
                .bit_order = NO_OS_SPI_BIT_ORDER_MSB_FIRST,
                .platform_ops = &spi_platform_ops,
                .extra = SPI_EXTRA,
        },
        .rdy_conv_timeout = 10000000,
        .config = {
                .clock_ctrl = {
                        .clocksel = AD4170_INTERNAL_OSC,
                        .clockdiv = AD4170_CLKDIVBY1,
                },
                .adc_ctrl = {
                        .mode = AD4170_MODE_CONT,
                        .multi_data_reg_sel = false,
                        .cont_read = AD4170_CONT_READ_OFF,
                },
                .channel_en = AD4170_CHANNEL(0),
                .map = {
                        [0] = {
                                .ainp = AD4170_AIN0,
                                .ainm = AD4170_AIN1,
                        },
                },
                /* Every setup is written out, so none may be left zeroed. */
                .setups = {
                        [0] = AD4170_SETUP_DEFAULT,
                        [1] = AD4170_SETUP_DEFAULT,
                        [2] = AD4170_SETUP_DEFAULT,
                        [3] = AD4170_SETUP_DEFAULT,
                        [4] = AD4170_SETUP_DEFAULT,
                        [5] = AD4170_SETUP_DEFAULT,
                        [6] = AD4170_SETUP_DEFAULT,
                        [7] = AD4170_SETUP_DEFAULT,
                },
                .ref_control = {
                        .ref_en = true,
                },
                .fir_control = {
                        .fir_length = 1,
                },
        },
};

ret = ad4170_init(&ad4170_desc, &ad4170_ip);
if (ret)
        goto error;

ret = ad4170_get_data24(ad4170_desc, &code);
if (ret)
        goto error_dev;

AD4170 no-OS IIO support

The AD4170 IIO driver sits on top of the AD4170 driver and exposes the device to IIO clients through the IIO library.

AD4170 IIO Device Configuration

Device Channels

The IIO driver describes one IIO_VOLTAGE channel named ch0 to ch15 per sequencer channel, regardless of what channel_en holds, so the channels the ADC converts can be picked at buffer enable time or at raw read time. A channel is indexed by its sequencer channel number rather than by the multiplexer inputs it converts, because several sequencer channels may convert the same input pair through different setups and the IIO channel ids would then collide. Samples are 24 bits stored in 32, little endian, signed when the setup the channel uses is bipolar and unsigned when it is unipolar.

ad4170_iio_init programs the sequencer channels that ad4170_init left alone, so that every channel can be enabled later on. Every entry of map therefore has to be initialized, even for channels the application does not intend to use: a zeroed map converts AIN0 against itself and reads as a near zero code. Use AD4170_OPEN for both inputs of an unused channel.

Channel Attributes

Each channel carries three attributes:

  • raw - a single conversion result read from the channel. The driver enables only that channel, switches the device to single conversion mode, waits for the result and then restores the previous mode and channel mask.

  • scale - the reference voltage in mV over 2 to the power of the effective bits, derived from the reference the setup selects, the bipolar/unipolar span and the PGA gain.

  • sampling_frequency - readable and writable. The rate is fCLK / (32 x FILTER_FS). Writing it converts the requested rate into a filter word and clamps it to what the selected filter accepts: 1 to 256 for plain sinc5, 4 to 65532 in steps of 4 for the others. FILTER_FS lives in the setup, so the new rate applies to every channel mapped to the same setup; give a channel its own setup to rate it independently.

Buffered Reads

On buffer enable the IIO driver programs the channel mask the buffer requests, clears multi_data_reg_sel and switches the device to continuous conversion mode, saving the previous mode, mask and data register selection. Samples are then read from the per-channel data registers as conversions become ready, and the saved configuration is restored when the buffer is disabled. The scan index of a channel matches its bit in the Channel_En register.

Debug Register Access

The IIO driver exposes byte-wise debug access to the whole register map. The byte address given by the client is mapped back to the register that holds it and to the byte position inside it, so multi-byte registers can be read and written one byte at a time.

Reference and Clock

vref_mv in struct ad4170_iio_dev_init_param is the external reference voltage in mV and is ignored for setups that select REFOUT, for which the internal 2.5 V is used. mclk_hz is the frequency of the clock wired to XTAL1/XTAL2; it is ignored when the internal oscillator is selected, for which 16 MHz is assumed, and has to be between 1 MHz and 17 MHz otherwise.

AD4170 IIO Driver Initialization Example

#define DATA_BUFFER_SIZE 400

static uint8_t iio_data_buffer[DATA_BUFFER_SIZE * AD4170_NUM_CHANNELS *
                               sizeof(uint32_t)];

struct ad4170_iio_dev *ad4170_iio_desc;
struct ad4170_iio_dev_init_param ad4170_iio_ip = {
        .ad4170_init_param = &ad4170_ip,
        .vref_mv = 2500,
};

struct iio_data_buffer read_buff = {
        .buff = (void *)iio_data_buffer,
        .size = sizeof(iio_data_buffer),
};

struct iio_app_desc *app;
struct iio_app_init_param app_init_param = { 0 };

ret = ad4170_iio_init(&ad4170_iio_desc, &ad4170_iio_ip);
if (ret)
        return ret;

struct iio_app_device iio_devices[] = {
        {
                .name = "ad4170",
                .dev = ad4170_iio_desc,
                .dev_descriptor = ad4170_iio_desc->iio_dev,
                .read_buff = &read_buff,
        }
};

app_init_param.devices = iio_devices;
app_init_param.nb_devices = NO_OS_ARRAY_SIZE(iio_devices);
app_init_param.uart_init_params = ad4170_uart_ip;

ret = iio_app_init(&app, app_init_param);
if (ret)
        goto iio_ad4170_remove;

return iio_app_run(app);